  Datasheet File OCR Text:
  abb control inc. 1 .1 ac 1600 ?3/00 pro m pro m miniature circuit breakers general information general information miniature circuit breakers (mcbs) are used throughout the world in all types of electrical installations. abb mcbs are recognized for use by underwriters laboratories standard ul1077 for supplementary circuit protectors in systems rated 240vac, 480vac and 600vac. devices are certified per csa c22.2. mcbs are approved per iec-898 and vde 0641, and certified under iec-947 and vde 0660 standards for use in systems rated 415vac or 690vac (s500 series). mcbs can be applied to 16 2 / 3 hz ?400hz and dc power systems. special direct current version mcbs include a permanent magnet for dc fault current interruption. these "uc" versions are rated 250/500vdc under ul1077/csa 22.2 no. 235. continuous current ratings are as low as 0.2 amperes and up to 125 amperes maximum. mcbs are of compact size and can be quickly mounted on standard 35mm din rail or can be front mounted by use of a front mounting kit. mcbs include line and load side terminals for conductors from 18 through 4awg (0.75 25 mm 2 ) for 40 amperes; up to 2awg for 50 and 63 amperes. mcbs can also be connected via busbar conductors which can be either upper or lower mounted for top feed or bottom feed. dual function terminals allow busbars to be connected with main incoming line conductors without separate lugs. accessories auxiliary devices can be added to s260, s270 and s280 series mcbs: ? shunt trips ? auxiliary contacts ? trip contacts ? aux/trip contacts ? undervoltage release accessory device modules can be field mounted to all above listed abb mcbs. auxiliary contacts are also available for the s500 series mcb. applications mcbs can be used for equipment protection, in commercial appliances, protection of control circuits against overcurrent faults, computer equipment and other computer peripheral devices. ul 1077 mcbs are recognized as supplementary protectors and are intended for use as overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided or not required. mcbs and accessories are recognized under ul file e76126. csa c22.2 mcbs and accessories are certified under csa c22.2 no. 235 per file lr98793. tripping characteristics time-current curves abb miniature circuit breakers are available with different trip characteristics, allowing for maximum system protection. b characteristic available with the s260 series has rated currents of 6 through 63 amperes in 10 steps. the "b" time- current curve is designed primarily for use in cable protection applications. instantaneous tripping occurs between approximately 3 to 5 times rated current in 50/ 60hz systems. this quick trip curve maximizes protection of control circuits under low short circuit fault levels that could damage control wiring. c characteristic available in the s260 series with rated currents up though 63 amperes and the s290 series with rated currents of 80, 100 and 125 amperes. the "c" time-current curve is designed for medium magnetic start-up currents. instantaneous tripping occurs between 5 and 10 times rated current in 50/60 hz systems. the "c" characteristic is also available in other s2 series mcbs. d characteristic the new magnetic trip action has an instantaneous trip point of approximately 15 times the breaker rating. thus, the s260-d can be a good protective solution for applications involving high in-rush transformers, motors and other high inductive systems. the 260-d is also suitable for any application where a high instantaneous trip point is desired. k characteristic the "k" time-current characteristic considers high magnetic start-up currents from motors, transformers and other equipment. instantaneous tripping occurs between 8 and 12 times rated current in 50/60hz systems. the "k" characteristic is available up through 63 amperes. the "k" curve offers the best protection for the broadest range of electrical systems. the higher magnetic trip settings maximizes protection while allowing for higher in-rush currents during system start-up. z characteristic also available up through 63 amperes, the "z" characteristic offers instantaneous tripping between 2 and 3 times rated current in 50/ 60hz systems. this trip characteristic is available in the s280 series with both the 480vac and 250/500vdc ratings. many applications require a very low short circuit trip settings in order to protect semiconductor or other sensitive devices and the "z" trip characteristic may provide maximum protection and service in these applications.
1 .2 abb control inc. ac 1600 3/00 pro m general information interruption ratings trip characteristics overview 120 vac 10ka 0.5 - 63a s260-b,c,d single pole 0.5 - 63a s270-k single pole 0.2 - 40a s280-k, z single pole 18ka 32 - 63a s500-b,c,d 26 - 45a s500-k 30ka 6 - 25a s500-b,c,d 0.15 - 25a s500-k 240 vac 6ka 0.5 - 63a s260-b,c,d single pole 0.5 - 63a s270-k single pole 50 - 63a s280-k, z single pole 10ka 0.5 - 63a s260-b,c,d multi pole 0.5 - 63a s270-k multi pole 0.2 - 40a s280-k,z single pole 18ka 32 - 63a s500-b,c,d 26 - 45a s500-k 30ka 6 - 25a s500-b,c,d 0.15 - 25a s500-k 277 vac 6ka 0.5 - 63a s260-b,c,d single pole 0.5 - 63a s270-k single pole 50 - 63a s280-k,z single pole 10ka 0.2 - 40a s280-k,z single pole 277/480 vac 6ka 0.5 - 63a s260-b,c,d multi pole 0.5 - 63a s270-k multi pole 40 - 63a s280-k,z multi pole 10ka 0.2 - 32a s280-k,z multi pole 60 vdc 10ka 0.5 - 63a s260-b,c,d single pole 0.5 - 63a s270-k single pole 125 vdc 10ka 0.5 - 63a s260-b,c,d multi pole 0.5 - 63a s270-k multi pole 0.2 - 63a s280uc-k,z single pole 250 vdc 4.5ka 0.2 - 63a s280uc-k,z single pole 500 vdc 4.5ka 0.2 - 63a s280uc-k,z multi pole voltage rated interrupting rated mcb comment capacity current type trip characteristics overview b 3 - 5x 1.25x s260, s500 c 5 - 10x 1.25x s260, s290, s500 d 10 - 20x 1.25x s260, s500 k 8 - 12x 1.05x s270,s280, s500 z 2 - 3x 1.05x s280 curve magnetic thermal series characteristic 1 characteristic 1 all values are relative to mcb's ampere rating. interruption ratings gen. info.
abb control inc. 1 .3 ac 1600 3/00 pro m general information tripping curves 0.01 0.1 10 100 1000 10,000 1 1 2 3 5 10 20 30 b 0.05 0.5 50 500 5000 5 dc ac 7 seconds multiple of rated current 1 2 3 5 10 20 30 c 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc ac 18 seconds multiple of rated current 1 2 3 5 10 20 30 d 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc ac seconds multiple of rated current 1 2 3 5 10 20 30 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 ac dc k seconds multiple of rated current 12 8 z 1 2 3 5 10 20 30 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 ac dc seconds multiple of rated current uc-z 1 2 3 5 10 20 30 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc seconds multiple of rated current 1 2 3 5 10 20 30 uc-k 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc seconds multiple of rated current gen. info.
1 .4 abb control inc. ac 1600 3/00 pro m general information construction details (s280 shown) space for identification marker tripping lever trip indicator operator operating mechanism electro-magnetic protection thermal protection-bimetal upper terminal fixed contact moving contact lower terminal din rail holder arc chamber gen. info.
abb control inc. 1 .5 ac 1600 ?3/00 pro m description the s2 series of miniature circuit breakers offer a compact solution to protection requirements. the breakers are recognized under standard ul 1077 as supplemental protective devices. the s2 devices are current limiting, din rail mounted and can offer a good equivalent to fused systems. the s2 is available with application-specific trip characteristics to provide maximum circuit protection. the breakers offer thermal-magnetic trip protection according to b, c, d, k and z characteristics. for the worldwide market, the breakers carry ul, csa, iec, ce and many other agency approvals and certifications. pro m miniature circuit breakers s260, s270, s280, s290 features current limiting fast breaking time (2.5 ?3.5 msec) unique bus connection system wide range of accessories available with variable depth handle mechanism optional z curve for scr protection ce certified and marked din rail or front plated mounting finger safe terminals multi-function terminals suitable for reverse feed ul 1077 and csa 22.2 277/480vac and 500vdc versions
1 .6 abb control inc. ac 1600 3/00 pro m ul 1077 csa c22.2 no. 235 vde 0641 iec-898 cable protection b switched neutral to create a miniature circuit breaker from stock items with a switched neutral, order standard mcb (usually a single or three pole version) and a neutral disconnect module, s2-nt, which can be field added to the mcb. s261-b6 s262-b6 s261-b6na s263-b6 s264-b6 s263-b6na s260 277/480 vac rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty discount schedule cb5b 6 s261-b6 $ 36 10 s261-b10 36 13 s261-b13 36 16 s261-b16 36 20 s261-b20 38 a10 4.5 25 s261-b25 38 32 s261-b32 40 40 s261-b40 42 50 s261-b50 48 63 s261-b63 56 6 s261-b6na 62 10 s261-b10na 62 13 s261-b13na 62 16 s261-b16na 62 20 s261-b20na 68 a5 9.0 25 s261-b25na 72 32 s261-b32na 74 40 s261-b40na 76 50 s261-b50na 90 63 s261-b63na 102 6 s262-b6 78 10 s262-b10 78 13 s262-b13 78 16 s262-b16 78 20 s262-b20 86 a5 9.0 25 s262-b25 88 32 s262-b32 94 40 s262-b40 98 50 s262-b50 112 63 s262-b63 128 6 s263-b6 $ 118 10 s263-b10 118 13 s263-b13 118 16 s263-b16 118 20 s263-b20 130 a 3 13.5 25 s263-b25 132 32 s263-b32 142 40 s263-b40 148 50 s263-b50 170 63 s263-b63 194 6 s263-b6na 142 10 s263-b10na 142 13 s263-b13na 142 16 s263-b16na 142 20 s263-b20na 162 a 2 18.0 25 s263-b25na 168 32 s263-b32na 176 40 s263-b40na 184 50 s263-b50na 212 63 s263-b63na 240 6 s264-b6 156 10 s264-b10 156 13 s264-b13 156 16 s264-b16 156 20 s264-b20 172 b 2 18.0 25 s264-b25 176 32 s264-b32 188 40 s264-b40 196 50 s264-b50 224 63 s264-b63 256 s260 b 0.01 0.1 10 100 1000 10,000 1 1 2 3 5 10 20 30 b 0.05 0.5 50 500 5000 5 dc ac 7 seconds multiple of rated current delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .7 ac 1600 3/00 pro m rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty c switched neutral to create a miniature circuit breaker from stock items with a switched neutral, order standard mcb (usually a single or three pole version) and a neutral disconnect module, s2-nt, which can be field added to the mcb. ul 1077 csa c22.2 - no. 235 vde 0641 iec-898 cable & equipment protection s260 277/480 vac 0.5 s261-c0.5 $ 42 1 s261-c1 42 1.6 s261-c1.6 42 2 s261-c2 42 3 s261-c3 42 4 s261-c4 42 6 s261-c6 42 8 s261-c8 42 10 s261-c10 42 a10 4.5 13 s261-c13 42 16 s261-c16 42 20 s261-c20 42 25 s261-c25 46 32 s261-c32 48 40 s261-c40 52 50 s261-c50 60 63 s261-c63 68 0.5 s261-c0.5na 84 1 s261-c1na 84 1.6 s261-c1.6na 84 2 s261-c2na 84 3 s261-c3na 84 4 s261-c4na 84 6 s261-c6na 84 8 s261-c8na 84 b5 9.0 10 s261-c10na 84 13 s261-c13na 84 16 s261-c16na 84 20 s261-c20na 84 25 s261-c25na 88 32 s261-c32na 90 40 s261-c40na 96 50 s261-c50na 112 63 s261-c63na 130 0.5 s262-c0.5 96 1 s262-c1 96 1.6 s262-c1.6 96 2 s262-c2 96 3 s262-c3 96 4 s262-c4 96 6 s262-c6 96 8 s262-c8 96 a5 9.0 10 s262-c10 96 13 s262-c13 96 16 s262-c16 96 20 s262-c20 96 25 s262-c25 106 32 s262-c32 106 40 s262-c40 116 50 s262-c50 136 63 s262-c63 152 discount schedule cb5 rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty 0.5 s263-c0.5 $ 138 1 s263-c1 138 1.6 s263-c1.6 138 2 s263-c2 138 3 s263-c3 138 4 s263-c4 138 6 s263-c6 138 8 s263-c8 138 10 s263-c10 138 a 3 13.5 13 s263-c13 138 16 s263-c16 138 20 s263-c20 138 25 s263-c25 156 32 s263-c32 158 40 s263-c40 174 50 s263-c50 200 60 s263-cs60 228 63 s263-c63 228 0.5 s263-c0.5na 200 1 s263-c1na 200 1.6 s263-c1.6na 200 2 s263-c2na 200 3 s263-c3na 200 4 s263-c4na 200 6 s263-c6na 200 8 s263-c8na 200 b 2 18.0 10 s263-c10na 200 13 s263-c13na 200 16 s263-c16na 200 20 s263-c20na 200 25 s263-c25na 206 32 s263-c32na 212 40 s263-c40na 224 50 s263-c50na 264 63 s263-c63na 304 0.5 s264-c0.5 218 1 s264-c1 218 1.6 s264-c1.6 218 2 s264-c2 218 3 s264-c3 218 4 s264-c4 218 6 s264-c6 218 8 s264-c8 218 b 2 18.0 10 s264-c10 218 13 s264-c13 218 16 s264-c16 218 20 s264-c20 218 25 s264-c25 234 32 s264-c32 238 40 s264-c40 260 50 s264-c50 300 63 s264-c63 338 s261-c1 s262-c1 s263-c1 s264-c1 1 2 3 5 10 20 30 c 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc ac 18 seconds multiple of rated current s260 c delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
1 .8 abb control inc. ac 1600 3/00 pro m s260 277/480 vac d switched neutral to create a miniature circuit breaker from stock items with a switched neutral, order standard mcb (usually a single or three pole version) and a neutral disconnect module, s2-nt, which can be field added to the mcb. ul 1077 csa c22.2 vde 0641 iec-898 cable & equipment protection rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty 0.5 s261-d0.5 $ 42 1 s261-d1 42 1.6 s261-d1.6 42 2 s261-d2 42 3 s261-d3 42 4 s261-d4 42 6 s261-d6 42 8 s261-d8 42 10 s261-d10 42 a10 4.5 13 s261-d13 42 16 s261-d16 42 20 s261-d20 42 25 s261-d25 46 32 s261-d32 48 40 s261-d40 52 50 s261-d50 60 63 s261-d63 68 0.5 s262-d0.5 96 1 s262-d1 96 1.6 s262-d1.6 96 2 s262-d2 96 3 s262-d3 96 4 s262-d4 96 6 s262-d6 96 8 s262-d8 96 a5 9.0 10 s262-d10 96 13 s262-d13 96 16 s262-d16 96 20 s262-d20 96 25 s262-d25 106 32 s262-d32 106 40 s262-d40 116 50 s262-d50 136 63 s262-d63 152 s261-d0.5 s262-d1 s263-d63 rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty 0.5 s263-d0.5 $ 138 1 s263-d1 138 1.6 s263-d1.6 138 2 s263-d2 138 3 s263-d3 138 4 s263-d4 138 6 s263-d6 138 8 s263-d8 138 a 3 13.5 10 s263-d10 138 13 s263-d13 138 16 s263-d16 138 20 s263-d20 138 25 s263-d25 156 32 s263-d32 158 40 s263-d40 174 50 s263-d50 200 63 s263-d63 228 discount schedule cb5 1 2 3 5 10 20 30 d 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc ac seconds multiple of rated current s260 d delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .9 ac 1600 3/00 pro m rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty k switched neutral to create a miniature circuit breaker from stock items with a switched neutral, order standard mcb (usually a single or three pole version) and a neutral disconnect module, s2-nt, which can be field added to the mcb. ul 1077 csa c22.2 - no. 235 vde 0641 iec-898 cable & equipment protection s270 277/480 vac 0.5 s271-k0.5 $ 42 1 s271-k1 42 1.6 s271-k1.6 42 2 s271-k2 42 3 s271-k3 42 4 s271-k4 42 5 s271-ks5 42 6 s271-k6 42 8 s271-k8 42 10 s271-k10 42 13 s271-k13 42 a10 4.5 15 s271-ks15 42 16 s271-k16 42 20 s271-k20 42 25 s271-k25 46 30 s271-ks30 48 32 s271-k32 48 40 s271-k40 52 50 s271-k50 60 60 s271-ks60 68 63 s271-k63 68 0.5 s271-k0.5na 84 1 s271-k1na 84 1.6 s271-k1.6na 84 2 s271-k2na 84 3 s271-k3na 84 4 s271-k4na 84 6 s271-k6na 84 8 s271-k8na 84 10 s271-k10na 84 b5 9.0 13 s271-k13na 84 16 s271-k16na 84 20 s271-k20na 84 25 s271-k25na 88 32 s271-k32na 90 40 s271-k40na 96 50 s271-k50na 112 63 s271-k63na 130 0.5 s272-k0.5 96 1 s272-k1 96 1.6 s272-k1.6 96 2 s272-k2 96 3 s272-k3 96 4 s272-k4 96 5 s272-ks5 96 6 s272-k6 96 8 s272-k8 96 10 s272-k10 96 a5 9.0 13 s272-k13 96 15 s272-ks15 96 16 s272-k16 96 20 s272-k20 96 25 s272-k25 106 30 s272-ks30 106 32 s272-k32 106 40 s272-k40 116 50 s272-k50 136 60 s272-ks60 152 63 s272-k63 152 s271-k2 s272-k2na s271-k10 rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty 0.5 s273-k0.5 $ 138 1 s273-k1 138 1.6 s273-k1.6 138 2 s273-k2 138 3 s273-k3 138 4 s273-k4 138 5 s273-ks5 138 6 s273-k6 138 8 s273-k8 138 10 s273-k10 138 13 s273-k13 138 a 3 13.5 15 s273-ks15 138 16 s273-k16 138 20 s273-k20 138 25 s273-k25 156 30 s273-ks30 158 32 s273-k32 158 40 s273-k40 174 50 s273-k50 200 60 s273-ks60 228 63 s273-k63 228 0.5 s273-k0.5na 200 1 s273-k1na 200 1.6 s273-k1.6na 200 2 s273-k2na 200 3 s273-k3na 200 4 s273-k4na 200 6 s273-k6na 200 8 s273-k8na 200 10 s273-k10na 200 b 2 18.0 13 s273-k13na 200 16 s273-k16na 200 20 s273-k20na 200 25 s273-k25na 206 32 s273-k32na 212 40 s273-k40na 224 50 s273-k50na 264 63 s273-k63na 304 0.5 s274-k0.5 218 1 s274-k1 218 1.6 s274-k1.6 218 2 s274-k2 218 3 s274-k3 218 4 s274-k4 218 6 s274-k6 218 8 s274-k8 218 b 2 18.0 10 s274-k10 218 13 s274-k13 218 16 s274-k16 218 20 s274-k20 218 25 s274-k25 234 32 s274-k32 238 40 s274-k40 260 50 s274-k50 300 63 s274-k63 338 s273-k10 s273-k20 s274-k20na discount schedule cb5 1 2 3 5 10 20 30 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 ac dc k seconds multiple of rated current 12 8 s270 k delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
1 .10 abb control inc. ac 1600 3/00 pro m rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty k switched neutral to create a miniature circuit breaker from stock items with a switched neutral, order standard mcb (usually a single or three pole version) and a neutral disconnect module, s2-nt, which can be field added to the mcb. ul 1077 csa c22.2 - no. 235 vde 0660 cable & equipment protection s280 277/480 vac 0.2 s281-k0.2 $ 54 0.3 s281-k0.3 54 0.5 s281-k0.5 54 0.75 s281-k0.75 54 1 s281-k1 54 1.6 s281-k1.6 54 2 s281-k2 54 3 s281-k3 54 4 s281-k4 54 6 s281-k6 54 8 s281-k8 54 a10 4.6 10 s281-k10 54 13 s281-k13 54 16 s281-k16 54 20 s281-k20 54 25 s281-k25 56 32 s281-k32 58 40 s281-k40 64 50 s281-k50 70 63 s281-k63 80 0.2 s282-k0.2 128 0.3 s282-k0.3 128 0.5 s282-k0.5 128 0.75 s282-k0.75 128 1 s282-k1 128 1.6 s282-k1.6 128 2 s282-k2 128 3 s282-k3 128 4 s282-k4 128 6 s282-k6 128 a5 9.2 8 s282-k8 128 10 s282-k10 128 13 s282-k13 128 16 s282-k16 128 20 s282-k20 128 25 s282-k25 130 32 s282-k32 134 40 s282-k40 134 50 s282-k50 162 63 s282-k63 182 rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty 0.2 s283-k0.2 $ 194 0.3 s283-k0.3 194 0.5 s283-k0.5 194 0.75 s283-k0.75 194 1 s283-k1 194 1.6 s283-k1.6 194 2 s283-k2 194 3 s283-k3 194 4 s283-k4 194 6 s283-k6 194 a3 13.9 8 s283-k8 194 10 s283-k10 194 13 s283-k13 194 16 s283-k16 194 20 s283-k20 194 25 s283-k25 196 32 s283-k32 200 40 s283-k40 214 50 s283-k50 246 63 s283-k63 280 s281-k16 s282-k1 s283-k63 discount schedule cb7 s280 k 1 2 3 5 10 20 30 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 ac dc k seconds multiple of rated current 12 8 delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .11 ac 1600 3/00 pro m s280 (w) for use with ring tongue terminal connectors 277/480 vac rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty k ul 1077 csa c22.2 - no. 235 vde 0660 cable & equipment protection 0.2 s281-k0.2w $ 54 0.3 s281-k0.3w 54 0.5 s281-k0.5w 54 0.75 s281-k0.75w 54 1 s281-k1w 54 1.6 s281-k1.6w 54 2 s281-k2w 54 3 s281-k3w 54 4 s281-k4w 54 6 s281-k6w 54 8 s281-k8w 54 a10 4.6 10 s281-k10w 54 13 s281-k13w 54 16 s281-k16w 54 20 s281-k20w 54 25 s281-k25w 56 32 s281-k32w 58 40 s281-k40w 64 50 s281-k50w 70 63 s281-k63w 80 0.2 s282-k0.2w 128 0.3 s282-k0.3w 128 0.5 s282-k0.5w 128 0.75 s282-k0.75w 128 1 s282-k1w 128 1.6 s282-k1.6w 128 2 s282-k2w 128 3 s282-k3w 128 4 s282-k4w 128 6 s282-k6w 128 a5 9.2 8 s282-k8w 128 10 s282-k10w 128 13 s282-k13w 128 16 s282-k16w 128 20 s282-k20w 128 25 s282-k25w 130 32 s282-k32w 134 40 s282-k40w 134 50 s282-k50w 162 63 s282-k63w 182 s281-k16w s282-k1w s283-k63w ? for use with ring tongue or cable terminals only. cannot be used with busbar system. 2 no charge when ordered with the s280(w). rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty 0.2 s283-k0.2w $ 194 0.3 s283-k0.3w 194 0.5 s283-k0.5w 194 0.75 s283-k0.75w 194 1 s283-k1w 194 1.6 s283-k1.6w 194 2 s283-k2w 194 3 s283-k3w 194 4 s283-k4w 194 6 s283-k6w 194 a 3 13.9 8 s283-k8w 194 10 s283-k10w 194 13 s283-k13w 194 16 s283-k16w 194 20 s283-k20w 194 25 s283-k25w 196 32 s283-k32w 200 40 s283-k40w 214 50 s283-k50w 246 63 s283-k63w 280 pkg of 20 screws s2-scr no charge catalog list item number price 2 screws (must be ordered separately!) s280(w) k 1 2 3 5 10 20 30 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 ac dc k seconds multiple of rated current 12 8 discount schedule cb7 delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
1 .12 abb control inc. ac 1600 3/00 pro m k ul 1077 vde 0660 csa 22.2 no. 235 cable and equipment protection rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty 0.2 s281uc-k0.2 $ 104 0.3 s281uc-k0.3 104 0.5 s281uc-k0.5 104 0.75 s281uc-k0.75 104 1 s281uc-k1 104 1.6 s281uc-k1.6 104 2 s281uc-k2 104 3 s281uc-k3 104 4 s281uc-k4 104 6 s281uc-k6 104 b10 4.6 8 s281uc-k8 104 10 s281uc-k10 104 16 s281uc-k16 104 20 s281uc-k20 104 25 s281uc-k25 108 32 s281uc-k32 110 40 s281uc-k40 116 50 s281uc-k50 136 63 s281uc-k63 152 0.2 s282uc-k0.2 242 0.3 s282uc-k0.3 242 0.5 s282uc-k0.5 242 0.75 s282uc-k0.75 242 1 s282uc-k1 242 1.6 s282uc-k1.6 242 2 s282uc-k2 242 3 s282uc-k3 242 4 s282uc-k4 242 b5 9.2 6 s282uc-k6 242 8 s282uc-k8 242 10 s282uc-k10 242 16 s282uc-k16 242 20 s282uc-k20 242 25 s282uc-k25 248 32 s282uc-k32 256 40 s282uc-k40 266 50 s282uc-k50 312 63 s282uc-k63 348 rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty 0.2 s283uc-k0.2 $ 370 0.3 s283uc-k0.3 370 0.5 s283uc-k0.5 370 0.75 s283uc-k0.75 370 1 s283uc-k1 370 1.6 s283uc-k1.6 370 2 s283uc-k2 370 3 s283uc-k3 370 4 s283uc-k4 370 b3 13.9 6 s283uc-k6 370 8 s283uc-k8 370 10 s283uc-k10 370 16 s283uc-k16 370 20 s283uc-k20 370 25 s283uc-k25 382 32 s283uc-k32 408 40 s283uc-k40 448 50 s283uc-k50 472 63 s283uc-k63 534 s281uc-k25 s282uc-k8 direct current applications the s280uc differs from standard miniature circuit breakers in that the uc versions include a permanent magnet which aids in the extinguishing of the arc during medium and high level faults. it is necessary to observe the correct polarity and current direction when connecting the uc breakers. two examples of correct connection are shown below. termination points are marked on all uc type mcbs, points one (1) and four (4) are negative and points two (2) and three (3) are positive. four pole breakers are also available for voltage reversal applications. maximum voltage between leads 250vdc 500vdc single pole two pole s281uc s282uc s283uc-k16 s280uc 500 vdc discount schedule cb7 l- l+ -1 +2 - + load l- l+ -1 +2 - + load 3+ 4- s280(uc) k 1 2 3 5 10 20 30 uc-k 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc seconds multiple of rated current delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .13 ac 1600 3/00 pro m z ul 1077 vde 0660 csa 22.2 no. 235 fast trip characteristic rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty switched neutral to create a miniature circuit breaker from stock items with a switched neutral, order standard mcb (usually a single or three pole version) and a neutral disconnect module, s2-nt, which can be field added to the mcb. see accessories page 1.18. direct current applications please refer to the chart on page 1.12.. 0.5 s281-z0.5 $ 70 1 s281-z1 70 1.6 s281-z1.6 70 2 s281-z2 70 3 s281-z3 70 4 s281-z4 70 6 s281-z6 70 8 s281-z8 70 b10 4.5 10 s281-z10 70 16 s281-z16 70 20 s281-z20 70 25 s281-z25 70 32 s281-z32 74 40 s281-z40 78 50 s281-z50 88 63 s281-z63 100 0.5 s282-z0.5 162 1 s282-z1 162 1.6 s282-z1.6 162 2 s282-z2 162 3 s282-z3 162 4 s282-z4 162 6 s282-z6 162 8 s282-z8 162 b5 9.2 10 s282-z10 162 16 s282-z16 162 20 s282-z20 162 25 s282-z25 184 32 s282-z32 170 40 s282-z40 176 50 s282-z50 206 63 s282-z63 232 0.5 s283-z0.5 244 1 s283-z1 244 1.6 s283-z1.6 244 2 s283-z2 244 3 s283-z3 244 4 s283-z4 244 6 s283-z6 244 8 s283-z8 244 b 3 13.9 10 s283-z10 244 16 s283-z16 244 20 s283-z20 244 25 s283-z25 248 32 s283-z32 254 40 s283-z40 266 50 s283-z50 306 63 s283-z63 344 s281-z16 s282-z32 s283-z32 rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty s280 & s280uc 277/480vac & 500vdc 0.5 s281uc-z0.5 $ 168 1 s281uc-z1 168 1.6 s281uc-z1.6 168 2 s281uc-z2 168 3 s281uc-z3 168 4 s281uc-z4 168 6 s281uc-z6 168 8 s281uc-z8 168 10 s281uc-z10 168 b10 4.6 16 s281uc-z16 168 20 s281uc-z20 168 25 s281uc-z25 170 32 s281uc-z32 176 40 s281uc-z40 188 50 s281uc-z50 216 63 s281uc-z63 242 0.5 s282uc-z0.5 390 1 s282uc-z1 390 1.6 s282uc-z1.6 390 2 s282uc-z2 390 3 s282uc-z3 390 4 s282uc-z4 390 6 s282uc-z6 390 8 s282uc-z8 390 b5 9.2 10 s282uc-z10 390 16 s282uc-z16 390 20 s282uc-z20 390 25 s282uc-z25 398 32 s282uc-z32 410 40 s282uc-z40 426 50 s282uc-z50 498 63 s282uc-z63 558 0.5 s283uc-z0.5 594 1 s283uc-z1 594 1.6 s283uc-z1.6 594 2 s283uc-z2 594 3 s283uc-z3 594 4 s283uc-z4 594 6 s283uc-z6 594 8 s283uc-z8 594 b 3 13.9 10 s283uc-z10 594 16 s283uc-z16 594 20 s283uc-z20 594 25 s283uc-z25 603 32 s283uc-z32 612 40 s283uc-z40 657 50 s283uc-z50 756 63 s283uc-z63 855 discount schedule cb7 480 vac class 500 vdc class s280 z uc-z 1 2 3 5 10 20 30 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc seconds multiple of rated current z 1 2 3 5 10 20 30 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 ac dc seconds multiple of rated current delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
1 .14 abb control inc. ac 1600 3/00 pro m s291-c80 s290-h11 c vde 0660 cable and equipment protection rated catalog list delivery sugg. wgt. oz. current number price class order (1 pc.) qty s290 277/480 vac discount schedule cb9 80 s291-c80 $ 138 100 s291-c100 144 b6 9.2 125 S291-C125 192 80 s292-c80 340 100 s292-c100 364 b 3 18.4 125 s292-c125 568 80 s293-c80 536 100 s293-c100 548 b 2 27.6 125 s293-c125 732 80 s294-c80 740 100 s294-c100 756 b 1 36.8 125 s294-c125 948 auxiliary contact s290-h11 72 b 1 1.75 bell alarm s290-s 112 b 1 1.75 shunt trip s290-a1 144 b1 6.2 for field mounting, left side, 110v 415vac s290-a2 144 b1 6.2 for field mounting, left side, 24 48vdc 480 vac class s290 c 1 2 3 5 10 20 30 c 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc ac 18 seconds multiple of rated current delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .15 ac 1600 3/00 pro m accessories busbars s260, s270, s280 l1.... l1 l2 l1 l2.... l1 l2 l3 l4 l1 l2 l3 l4.... l1 l2 l3 l1 l2 l3.... l1 l2 l3 l1 l2 l1 l1 l2 l3 l4 1 phase 2 phase 3 phase 4 phase acc. discount schedule cb8 amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 55 12 207 sz-ks1/12 $ 12 10 0.6 55 56 988 sz-ks1/56 36 a 52.6 85 56 988 sz-ks2/56 46 55.2 110 56 988 sz-vb45.32 68 510.0 50 58 1035 psb-end3 sz-psb54n $ 122 14.4 65 58 1035 psb-end3 sz-psb56n 122 a119.1 50 12 213 psb-53ul 40 4.0 amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 12 213 psb-3ul $ 60 34.3 65 60 1065 psb-end5 sz-psb4n 130 a121.4 50 60 1065 psb-end6 sz-psb12n 176 134.2 amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 60 1035 psb-end4 sz-psb62n $ 204 a1 23.2 65 60 988 psb-end4 sz-psb64n 236 31.6 amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) uninsulated copper bar mounts flush with bottom edge of circuit breakers. for use on load side (bottom) of s260, s270, s280 and line side (top) of s280 mcbs. insulated busbar assembly contains 2 separate circuits for use with 1, 1+n or 2 pole mcbs. for use on load side (bottom) of s260, s270, s280 and line side (top) of s280 mcbs. insulated busbar assembly contains 3 separate circuits for use with 1 or 3 pole mcbs. for use on load side (bottom) of s260, s270, s280 and line side (top) of s280 mcbs. insulated busbar assembly contains 4 separate circuits for use with 3+n1 or 4 pole mcbs. for use on load side (bottom) of s260, s270, s280 and line side (top) of s280 mcbs. delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
1 .16 abb control inc. ac 1600 3/00 pro m acc. accessories busbars s260, s270, s280 l1 l1 l1 l2 l3 l1 l2 l1 l2 l3 l1 l1 l2 l1 l2 l1 l2.... l2 l3 l1 l2 l3.... l1 l2 l3.... l1 l1.... 1 phase with 1 auxiliary 3 phase for 1 pole mcb?s with 1 auxillary 2 phase with 1 auxillary 3 phase with 1 auxillary discount schedule cb8 amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 39 1044 psb-end3 sz-ks3/39n $ 50 a1 7.4 65 39 1044 psb-end3 sz-ks4/39n 56 a 1 10.1 amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 65 48 1065 sz-psb92n 174 b 1 23.2 amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 48 980 psb-end3 sz-psb50n $ 124 b115.8 65 48 980 psb-end3 sz-psb52n 158 a122.6 uninsulated copper bar mounts flush with bottom edge of circuit breakers. for use on load side (bottom) of s260, s270, s280 and line side (top) of s280 mcbs. insulated busbar assembly contains 3 separate circuits for use with 1 or 3 pole mcbs. for use on load side (bottom) of s260, s270, s280 and line side (top) of s280 mcbs. insulated busbar assembly contains 4 separate circuits for use with 3+n1 or 4 pole mcbs. for use on load side (bottom) of s260, s270, s280 and line side (top) of s280 mcbs. amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 58 1044 psb-end3 sz-psb46n $ 124 b 1 16.1 65 58 1044 psb-end3 sz-psb48n 158 b 1 22.1 insulated busbar assembly contains 2 separate circuits for use with 1, 1+n or 2 pole mcbs. for use on load side (bottom) of s260, s270, s280 and line side (top) of s280 mcbs. delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .17 ac 1600 3/00 pro m accessories busbars s260, s270, s280 acc. l1 l2 l3 l1 l2 l3.... l1 l2 l3 l1 n l2 n l3 n l1 n l2.... n l1 l2 l3 busbar end caps bus tooth covers p/n: sz-bsk5 5-poles busbar mounted terminal block p/n: sz-esk2 1-pole 3 phase 3 phase + n, for use with 2 pole mcb ? s on 3 phase / 4w system mcb busbar accessories l1.... l1 3 ph + n, for use with 2 pole mcb ? s on 3 ph / 4w system discount schedule cb8 catalog list delivery suggested weight description number price class order qty. ounce qty. (2 pc.) psb-end3 busbar end caps psb-end4 $ 2 a10 psb-end5 psb-end6 busbar tooth covers sz-bsk5 4 a10 (shrouds unused portion of busbar) iec busbar mounted terminal block sz-esk2 10 a11.0 1 pole, for use on all busbars insulated busbar assembly contains 3 separate circuits for use with 1, 2+n or 3 pole mcbs. for use on line side (top) of s260 and s270 mcbs. amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 12 213 sz-psb21 $ 40 4.5 50 60 1065 sz-psb22 130 a1 21.4 65 12 213 sz-psb23 50 6.0 65 60 1065 sz-psb24 176 34.2 amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 58 1048 psb-end4 sz-psb58n $ 198 b 1 22.3 65 58 1048 psb-end4 sz-psb60n 238 a 1 30.8 insulated busbar assembly contains 4 separate circuits for use with 1+n or 2 pole mcbs. for use on load side (bottom) of s260, s270, s280 and line side (top) of s280 mcbs. delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery insulated busbar assembly contains 1 circuit for use with 1 pole mcbs. for use on line side (top) of s260 and s270 mcbs. amp number busbar end cap catalog list delivery suggested weight rating of length catalog number price class order qty. ounce poles number quantity (2 pc.) 50 12 202 sz-ks16/12n $ 13 a1 1.5 50 56 1007 sz-ks16/56n 55 9.0
1 .18 abb control inc. ac 1600 3/00 pro m accessories s260, s270 & s280 s2-h11 s2-a1 s2-bm1 s2-s s2-s/h s2-nt electrical catalog list delivery suggested wgt. oz. accessories number price class order quantities (1 pc.) auxiliary contacts for field mounting: left side 1 n.o./ 1 n.c. s2-h11 $ 36 2 n.o. s2-h20 36 2 n.c. s2-h02 36 a11.4 1 n.o./ 2 n.c. s2-h12 54 2 n.o./ 1 n.c. s2-h21 54 2 n.o./ 1 n.c. (low voltage) s2-h21kl 60 the s2-h11 auxiliary switch can be field mounted to any s260, s270 or s280 series breaker. the auxiliary contacts will signal w hether the breaker is in the on or off position. the contacts are rated 6a/240 vac and 1.5a/110 vdc. minimum operating voltage is 12 vac/v dc. bell alarm for field mounting, left side s2-s 48 a11.4 the s2-s bell alarm includes a set of contacts that will only signal when the breaker has tripped. typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occured. the bell alarm also includes a test button for te sting the alarm contacts without opening the breaker. the contact is rated 6a/240 vac and 1.5a/110 vdc. minimum operating voltage is 12 vac/vdc . bell alarm with auxiliary contact for field mounting, left side s2-s/h 58 a11.4 the s2-s/h bell alarm with auxiliary contact device combines one set of bell alarm contacts with one set of auxiliary contacts (n.o.). shunt trip for field mounting, left side 12-60 vac (12-60vdc) s2-a1 138 a15.2 110-415 vac (110-250 vdc) s2-a2 for remote tripping of breaker, a shunt trip device can be added to the mcb. the solenoid device opens the breaker after contro l voltage is applied. shunt trips are available depending on control system voltage (12-415 vac/vdc). undervoltage release for field mounting, left or right side 12v s2-bm1 24v s2-bm2 48v s2-bm3 216 a15.2 110v s2-bm4 220v s2-bm5 380v s2-bm6 when control voltage drops below approximately 50% of rated voltage, the s2-bm opens the breaker. the breaker can not be operat ed unless proper control voltage is first applied to the uvr coil. similar in size and mounting to the shunt trip accessory; can be left or right side mounted. hand operated neutral disconnect for field mounting, right side, 40a max. s2-nt 27 a11.4 when switching of neutral with breaker contacts is desired, the neutral module s2-nt can be added to any s260, s270 or s280 mcb . the neutral connection makes before the mcb contacts connect line to load. makes contact before mcb contacts close. must be opened manually. factory mounting all accessories can be easily mounted in the field. for factory mounting of any accessory devices, add $30 list to total price per breaker. to create complete catalog number, take suffix of accessory device following s2- and add suffix to end of breaker part number. multiple suffixes must be added in alphabetical order. example: s272-k20a1 $ 264 (2 pole, 20a breaker with type a1 shunt trip) s272-k20 @ $96 + a1 @ $138 + factory mounting @ $30 = $264 s272-k20a2h11 $ 300 (2 pole, 20a breaker with type a2 shunt trip and h11 aux. contacts) s272- k20 @ $96 + a2 @ $138 + h11 @ $36 + factory mounting @ $30 = $300 auxiliary contacts and shunt trips may be mounted in combination. discount schedule cb8 note: above accesssories are for use with types s260, s270 and s280 breakers only. acc. delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .19 ac 1600 3/00 pro m accessories s260, s270, s280 electrical catalog list delivery suggested wgt. oz. accessories number price class order quantities (1 pc.) sa1 sa2 sz-ast35 mb-3pd mb-cl s500-me2 discount schedule cb8 front mounting kit for 2 poles s500-me1 $ 60 2.1 for 2 5 poles s500-me2 70 a1 2.9 for 2 10 poles s500-me3 80 3.6 optional rear terminals (2 per kit) mb-2rt 16 1.5 includes flange, mounting rail, terminals for rear connection and hardware. front mounting clip for 1 4 poles mb-cl 35 a12 simple mounting clip for up to four module mounting. front mounting bracket for 1 3 poles mb-3pd 35 a12.5 for flush mounting of three pole mcbs: includes hardware. pin-type connector 2awg (35 mm 2 ) sz-ast35 9 a100.5 needed for connecting large cable 2awg (35mm 2 ) and busbar on same breaker. locking device adaptor only sa1 9 a10 0.7 padlock only w/ 2 keys sa2 19 0.1 allows breaker to be locked in on or off position. labeling accessory 1 sheet = 100 blank labels 1 sheet = 100 numbered labels stl-st 74 a1 snaps into rail indent on front of mcb label holder & labels includes 100 label carriers. enclosure, ip55 for 4 modules 12644 84 8.1 for 6 modules 12646 98 a1 10.8 for 10 modules 12650 126 20.4 for 20 modules 12652 210 41.0 molded plastic complete with mounting rail and knock-outs for cable entries. blanking plates single pole (set of 10) bp-1p 6 a1 twelve pole (snap-off, set of 1) bp-12p 7 terminal covers for 2 modules pcd2 32 2.0 for 4 modules pcd4 45 a1 2.8 for 6 modules pcd6 56 3.4 for 8 modules pcd8 66 4.1 for additional protection against accidental contact. includes integrated mounting rail. handle mechanism rhs2-m 76 a19.2 for use with 2, 3 and 4 pole s2 mcbs and disconnect switch selector handles with 5 mm shaft. mounting rail universal mounting smr-39 21 a18 35mm din rails are available in 39-inch strips (1 meter). acc. delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
1 .20 abb control inc. ac 1600 ?3/00 pro m mounting universal mounting position using snap-on mounting to standard 35x7.5 mm din rail. miniature circuit breakers (mcbs) can also be mounted to front of door using a panel cut-out with breaker handle protruding through panel opening for external operation. special front mounting kit type me is available (see page 2.12). connection terminals are suitable for solid or flexible conductors from 18 to 4 awg (0.75 to 25 mm 2 ) with no busbar connected. when maximum busbar size of 36 mm 2 is used, maximum cable is 6 awg (16 mm 2 ). maximum tightening torque of 17.5 in-lb (2 nm) for line/load terminals and 4.5 in-lb (0.5nm) for accessory device terminals. operation mcbs are switched on by moving the handle to the upper position. stamped onto the handle switch, a i is visible confirming that the breaker is closed. the mcbs are trip-free, if the handle is being forced to the on position, the breaker will still trip under fault conditions. the o marking indicates that the breaker is in the off position. the mcb is now open and the load is disconnected from line power. when a breaker has tripped, the mcb handle should first be set to the full off position to make certain the trip mechanism has been reset. once the fault has been determined and cleared the mcb can again be switched on . maintenance abb miniature circuit breakers require no special maintenance; only normal electrical system maintenance procedures are required. removing mcb mounting mcb technical data mounting and operating instructions auxiliary switch bell alarm with auxiliary contact shunt trip and undervoltage release possible mounting arrangements of mcb accessories remove seal add shunt trip to mcb attach with spring clamps set mcb to off position, insert metal pin as break out opening on side of mcb noted above with arrow and mount device to set breaker to on position and remove seal side of mcb attach with spring clamps set mcb to off position and mount set breaker to on position break out opening on side of mcb auxiliary switch to side of breaker attach with spring clamps mcb h11 s s/h auxiliary switch/bell alarm neutral disconnect nt mcb shunt trip and/or undervoltage release a bm bm mcb h11 s s/h a bm shunt trip or undervoltage release mounted with auxiliary switch tech data
abb control inc. 1 .21 ac 1600 3/00 pro m lower terminals can be bussed together with single phase or multi-phase busbars as shown. upper terminals can also be busbar connected. dual function terminals provided in open position for connection to busbars. pressing on screw head opens box terminal for cable insertion. only the lower terminal is dual function. terminals allow for connection of cable 18-4 awg. conductors of different sizes may also be used in same terminal. up to five conductors, 16 awg each, can be safely connected per terminal. lower terminal can also be bussed with solid round conductor. cables can be connected to box terminals in addition to busbar connections on lower, dual function terminals. technical data busbars & connectors connection methods tech data
1 .22 abb control inc. ac 1600 3/00 pro m approvals: ul 1077 1077 1077 1077 csa c22.2 no.235 c22.2 no. 235 c22.2 no. 235 c22.2 no. 235 vde 0641, 0660 0660 0660 0660 iec 898, 947 898, 947 898, 947 898, 947 no. of poles: 1,2,3,4 1+n,3+n 1,2,3 1,2,3,4, 1+n,3+n 1,2,3,4,1+n,3+n tripping characteristic: b c,d k k rated currents: 6 to 63a 0.5 to 63a 0.5 to 63a 0.2 to 63a minimum operating voltage: 12v 12v 12v 12v ul/csa rated voltage & single pole multi pole single pole multi pole single pole multi pole single pole multi pole interrupting capacity 120vac 10ka 10ka 10ka 10ka for 0.2-40a 6ka for 50-63a 240vac 6ka 10ka 6ka 10ka 6ka 10ka 10ka for 0.2-40a 10ka for 0.2-32a 6ka for 50-63a 6ka for 40-63a 277vac 6ka 6ka 6ka 10ka for 0.2-40a 277/480 vac 6ka 6ka 6ka 10ka for 0.2-32a 6ka for 40-63a 60vdc 10ka 10ka 10ka 10ka 10ka 10ka 125vdc 10ka 10ka 10ka frequency: 50/60hz (see below) 50/60hz (see below) 50/60hz (see below) 50/60hz (see below) rated voltage iec single pole 240/415vac 240/415vac 240/415vac 240/415vac 60vdc 60vdc 60vdc 60vdc iec multi-pole 415vac 415vac 415vac 415vac 110vdc 110vdc 110vdc 110vdc protection category: ip20 ip20 ip20 ip20 depth of unit per din 43880: 68 mm 68 mm 68 mm 68 mm mounting position: optional optional optional optional standard mounting: 35 mm din rail 35 mm din rail 35 mm din rail 35 mm din rail terminals: conductors from 18-4awg conductors from 18-4awg conductors from 18-4awg conductors from 18-4awg (0.75 25sq mm ) (0.75 25sq mm ) (0.75 25sq mm ) (0.75 25sq mm ) 50a and above 50a and above 50a and above 50a and above conductors from 18-2awg conductors from 18-2awg conductors from 18-2awg conductors from 18-2awg (0.75 35sq mm ) (0.75 35sq mm ) (0.75 35sq mm ) (0.75 35sq mm ) service life at rated load: 20,000 operations 20,000 operations 20,000 operations 20,000 operations ambient temperatures: -25 c to +55 c-25 c to +55 c-25 c to +55 c-25 c to +55 c shock resistance: 10g minimum of 20 impacts, 10g minimum of 20 impacts, 10g minimum of 20 impacts, 10g minimum of 20 impacts, shock duration of 13ms shock duration of 13ms shock duration of 13ms shock duration of 13ms vibration resistance: 5g, minimum of 30 minutes 5g, minimum of 30 minutes 5g, minimum of 30 minutes 5g, minimum of 30 minutes disconnecting neutral rating: 6ka switching 6ka switching 6ka switching technical data s260, s270, & s280 item s260-b s260-c, -d s270-k s280-k tech data influence of frequency on electro-magnetic trips magnetic trip values shown on trip curves are valid for 50/60hz applications. for frequencies other than 50/60hz, the magnetic (instantaneous) trip values are increased by the factor given below: 16 2/3 - 60hz 100hz 200hz 400hz dc approx. factor 1 1.1 1.2 1.5 1.5 thermal tripping is independent of frequency.
abb control inc. 1 .23 ac 1600 3/00 pro m technical data s280, s280uc, s290 approvals: ul 1077 1077 1077 csa c22.2 no. 235 c22.2 no. 235 c22.2 no. 235 vde 0660 0660 0660 0660 iec 898,947 898, 947 898, 947 898 no. of poles: 1,2,3 1,2,3,4 1,2,3 1,2,3,4 tripping characteristic: k z z c rated currents: 0.2 to 63a 0.5 to 63a 0.5 to 63a 80 to 125a minimum operating voltage: 12v 12v 12v 12v ul/csa rated voltage & single pole multi pole single pole multi pole single pole multi pole interrupting capacity 120vac 6ka for 0.2-40a 10ka for 0.2-40a 6ka for 0.2-40a 5ka for 50-63a 6ka for 50-63a 5ka for 50-63a 240vac 6ka for 0.2-40a 6ka for 0.2-40a 10ka for 0.2-40a 10ka for 0.2-32a 6ka for 0.2-40a 6ka for 0.2-40a 5ka for 50-63a 5ka for 50-63a 6ka for 50-63a 6ka for 40-63a 5ka for 50-63a 5ka for 50-63a 277vac 4.5ka for 0.2-40a 10ka for 0.2-40a 4.5ka for 0.2-40a 5ka for 50-63a 6ka for 50-63a 5ka for 50-63a 277/480 vac 4.5ka for 0.2-40a 10ka for 0.2-32a 4.5ka for 0.2-40a 5ka for 50-63a 6ka for 40-63a 5ka for 50-63a 60vdc 10ka 10ka 10ka 10ka 125vdc 10ka 10ka 10ka 10ka 250vdc 4.5ka 4.5ka 4.5ka 4.5ka 500vdc 4.5ka 4.5ka frequency: 50/60hz (see below) 50/60 hz (see below) 50/60hz (see below) 50/60hz (see below) rated voltage iec single pole 240/415vac 240/415vac 240/415vac 230/440vac 220vdc 60vdc 220vdc 60vdc iec multi-pole 415vac 415vac 415vac 440vac 440vdc 110vdc 440vdc 110vdc protection category: ip20 ip20 ip20 ip20 depth of unit per din 43880: 68 mm 68 mm 68 mm 70 mm mounting position: optional optional optional optional standard mounting: 35 mm din rail 35 mm din rail 35 mm din-rail 35 mm din-rail terminals: conductors from 18-4awg conductors from 18-4awg conductors from 18-4awg conductors from 14-1/0awg (0.75 25sq mm ) (0.75 25sq mm ) (0.75 25sq mm ) (1.5 50sq mm ) 50a and above 50a and above 50a and above conductors from 18-2awg conductors from 18-2awg conductors from 18-2awg (0.75 35sq mm ) (0.75 35sq mm ) (0.75 35sq mm ) service life at rated load: 20,000 operations 20,000 operations 20,000 operations 10,000 operations ambient temperatures: -25 c to +55 c-25 c to +55 c-25 c to +55 c-5 c to +45 c shock resistance: 10g minimum of 20 impacts, 10g minimum of 20 impacts, 10g minimum of 20 impacts, 30g minimum of 20 impacts, shock duration of 13ms shock duration of 13ms shock duration of 13ms shock duration of 13ms vibration resistance: 5g, minimum of 30 minutes 5g, minimum of 30 minutes 5g, minimum of 30 minutes 60m/s 2 , at 10 150 hz item s280uc-k s280-z s280uc-z s290-c tech data influence of frequency on electro-magnetic trips magnetic trip values shown on trip curves are valid for 50/60hz applications. for frequencies other than 50/60hz, the magnetic (instantaneous) trip values are increased by the factor given below: 16 2/3 - 60hz 100hz 200hz 400hz dc approx. factor 1 1.1 1.2 1.5 1.5 thermal tripping is independent of frequency.
1 .24 abb control inc. ac 1600 3/00 pro m s260-b s280-k s270-k let-through values i 2 t for other curves, please contact abb control. version i 2 t i peak s260b td9980 s260c td9981 s260d td9982 s270k td9972 td9950 s280k td9978 s280z td9979 s290c td9985 version amps time-current trip s260b 6 - 63 td9725 s270k 0.5 - 8 td9705 10 - 40 td9706 50 - 63 td9707 s280k 0.2 - 8 td9708 10 - 40 td9709 50 - 63 td9710 s280z 0.5 - 63 td9711 technical data let-through values description all abb miniature circuit breakers substantially reduce the maximum let-through current from the peak available short circuit current. i k - rms current of fault i d - max let-through of mcb v n - system voltage v b - arc voltage of mcb t k - breaking time of mcb tech data
abb control inc. 1 .25 ac 1600 3/00 pro m type b, c, d type k, z current carrying capacity of type b , c , d , k and z thermal trip characteristics as a function of ambient temperature. technical data temperature derating factors terminal markings terminal markings input optional from top or bottom. 1 pole 1 2 2 pole 1 2 3 4 3 pole 1 2 3 4 5 6 1 pole & na 1 2 3n 4n 3 pole & na 1 2 3 4 5 6 7n 8n a1 / a2 c2 c1 bell alarm 98 95 96 12 11 14 aux sw 1 2 i s/h h11 13 14 21 22 bm d2 d1 u tech data
1 .26 abb control inc. ac 1600 3/00 pro m technical data breaker resistance values & wire size comparison miniature circuit breaker resistance values ampere milliohms rating s260-b s270-k s280-k s280-z 0.2 33300 0.3 19700 0.5 6340 5020 10100 0.75 2400 1.0 1550 1390 2270 1.6 695 612 1100 2 460 450 619 3 165 147 202 4 120 112 149 6 55 52 54.1 104 8 15 38 33.8 53.9 10 13.3 12.6 15.1 17.5 12 13.3 12.6 16 7.0 7.7 8.1 10.9 20 6.25 6.7 5.27 6.0 25 5.0 4.6 3.97 4.1 32 3.6 3.5 2.65 2.81 40 3.0 2.8 2.44 2.55 50 1.2 1.15 1.15 1.77 63 1.4 0.70 0.70 1.31 1.0 8 16 (1.3) 10 1.5 12 14 (2.1) 15 2.5 20 12 (3.3) 20 4 25 10 (5.3) 30 6 32 8 (8.4) 50 10 50 6 (13.3) 65 16 65 4 (21.2) 85 25 85 3 (26.7) 100 2 (33.6) 115 35 115 ampacities for awg wire are based on copper cable rated 75 c, except for 16awg which is based on 60 c wire. taken from ul508 table 52.2. consult applicable standards for futher detail and information. mm awg (mm ) amps / ul amps / iec comparison of iec and awg wire sizes tech data
abb control inc. 1 .27 ac 1600 3/00 pro m approximate dimensions s260, s270, s280, s290 0.58 (14.8) 0.69 (17.5) 0.69 (17.5) c l 0.69 (17.5) 0.69 (17.5) 2.07 (52.5) 3.54 (90.0) 2.72 (69.0) 2.68
(68.0) 1.77 (45.0) 2.95
(74.9) 1.46
(37.1) 1.98
(50.2) c l upper term. c l lower term. c l 0.58 (14.8) 0.69 (17.5) 0.69 (17.5) 3.54 (90.0) 2.72 (69.0) c l 0.69 (17.5) 0.69 (17.5) 2.07 (52.5) 2.95
(74.9) 2.68
(68.0) 1.77 (45.0) 1.46
(37.1) 1.98
(50.2) lower term. c l upper term. c l s280 s260 & s270 s290 00.00 00.00 inches millimeters dims -a1, -a2 -h -s 1.06 27 2.13 54 3.19 81 0.69 17.5 0.35 9 0.35 9 1.97 50 1.03 26 1.77 45
1 .28 abb control inc. ac 1600 3/00 pro m mb-cl approximate dimensions accessories 00.00 00.00 inches millimeters mb-3pd rhs2-m c.l. 1.77 45 2.26 57.5 c.l. 0.69 17.5 1.38 35 2.07 52.5 1.77 45 d bkt. mt. holes 0.25 dia. typ 2 c l c l 3.25 2.12 ( 3p ) 1.87 0.74 ( 1p ) 1.43 ( 2p ) breaker cut out c l c l 3.54 90 0.10 2.5 1.89 48 0.34d 8.6d 0.80 20.3 1.77 45 0.97 24.7 1.38 35 2.07 52.5 0.83 21 0.01 0.25 0.63 16 3.26 82.5 4.36 110.4 0.27 6.9 0.69 17.5 0.69 17.5 0.35 8.8 0.35 8.8 h11 (1/2x) h/s (1/2x) a (1x) u (1x) left side mtd left or right side mtd 3-pole mcb accessories dims
abb control inc. 1 .29 ac 1600 3/00 pro m 12644 approximate dimensions accessories 00.00 00.00 inches millimeters 12646 12650 12656 4.13 105 4.92 125 4.92 125 7.09 180 4.13 105 4.92 125 6.30 160 7.09 180 4.13 105 4.92 125 230 9.06 7.09 180 9.84 250 12.60 320 6.09 155 5.32 135 dims
1 .30 abb control inc. ac 1600 3/00 pro m cross-reference x-ref s160l s260b same pole spacing same trip characteristic as l s160k s270k same pole spacing same trip characteristic as k s270 is 6ka ic s210l s260b same pole spacing same trip characteristic as l s260b is 6ka ic s210k s280k same pole spacing same trip characteristic as k s280k is 6ka ic s210z s280z same pole spacing same trip characteristic as z s250l s260b same pole spacing same trip characteristic as l s210-uck s280uc-k same pole spacing same trip characteristic as k s210-ucz s280uc-z same pole spacing same trip characteristic as z s220-k s500-k different pole spacing same trip characteristic as k s230-b s260-b same pole spacing same trip characteristic as b older suggested physical electrical version replacement comparison comparison series many older styles of abb miniature circuit breakers have been replaced by new and improved versions. many of these newer styles can be directly interchanged, both electrically and physically, with the older version. there are also many international styles of abb circuit breakers which are not normal stock items and may be interchanged with stocked abb versions. note: mcb types s260/270 and s280 can be raised to the same height as older style s210 series mcbs through the use of a height adjuster (sz-es68/83; $ 30 list per 20). the height adjustor snaps onto the din rail and raises the height of components 68mm to match that of the s210 series (83m m).
abb control inc. 1 .31 ac 1600 ?3/00 pro m pro m miniature circuit breakers s500 description increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding safety, reliability and switching capacities. the s500 heavy-duty circuit breaker fulfills these requirements by virtue of its technical features. it is equipped with a thermal and/or electromagnetic release to protect circuits, motors, switchgear and systems from the effects of overload and short-circuit currents. for the worldwide market, the s500 breakers carry ul, csa, iec, ce and many other agency approvals. features high breaking capacity energy-limiting current-limiting extremely fast breaking time optimal selectivity various versions for special applications compact dimensions, din cap size easy and quick to install easy to connect; finger safe terminals wide range of accessories ul 1077 recognized 600vac and 500vdc versions
1 .32 abb control inc. ac 1600 3/00 pro m rated catalog list delivery weight current number price class (oz.) 1 pc 6 s501-b6 $ 168 10 s501-b10 168 13 s501-b13 168 16 s501-b16 168 20 s501-b20 168 b8.90 25 s501-b25 168 32 s501-b32 168 40 s501-b40 168 50 s501-b50 186 63 s501-b63 202 6 s502-b6 328 10 s502-b10 328 13 s502-b13 328 16 s502-b16 328 20 s502-b20 328 b 17.85 25 s502-b25 328 32 s502-b32 328 40 s502-b40 328 50 s502-b50 362 63 s502-b63 392 6 s503-b6 478 10 s503-b10 478 13 s503-b13 478 16 s503-b16 478 20 s503-b20 478 b 25.36 25 s503-b25 478 32 s503-b32 478 40 s503-b40 478 50 s503-b50 526 63 s503-b63 574 ul 1077 csa c22.2 vde 0641 iec 947-2 b rated catalog list delivery weight current number price class (oz.) 1 pc 6 s501-c6 $ 168 10 s501-c10 168 13 s501-c13 168 16 s501-c16 168 20 s501-c20 168 b8.90 25 s501-c25 168 32 s501-c32 168 40 s501-c40 168 50 s501-c50 184 63 s501-c63 202 6 s502-c6 328 10 s502-c10 328 13 s502-c13 328 16 s502-c16 328 20 s502-c20 328 b 17.85 25 s502-c25 328 32 s502-c32 328 40 s502-c40 328 50 s502-c50 362 63 s502-c63 392 6 s503-c6 478 10 s503-c10 478 13 s503-c13 478 16 s503-c16 478 20 s503-c20 478 b 25.36 25 s503-c25 478 32 s503-c32 478 40 s503-c40 478 50 s503-c50 526 63 s503-c63 574 ul 1077 csa c22.2 vde 0641 iec 947-2 c s500 277/600 vac s501-c16 s502-c6 s503-c10 discount schedule cb10 s500 b & c 0.01 0.1 10 100 1000 10,000 1 1 2 3 5 10 20 30 b 0.05 0.5 50 500 5000 5 dc ac 7 seconds multiple of rated current 1 2 3 5 10 20 30 c 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc ac 18 seconds multiple of rated current delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .33 ac 1600 3/00 pro m s500 277/600 vac rated catalog list delivery wgt. oz. current number price class (1 pc.) 13 s501-d13 $ 190 16 s501-d16 190 20 s501-d20 190 25 s501-d25 190 b8.90 32 s501-d32 190 40 s501-d40 190 50 s501-d50 210 63 s501-d63 226 13 s502-d13 372 16 s502-d16 372 20 s502-d20 372 25 s502-d25 372 b 17.85 32 s502-d32 372 40 s502-d40 372 50 s502-d50 408 63 s502-d63 442 13 s503-d13 544 16 s503-d16 544 20 s503-d20 544 25 s503-d25 544 b 25.36 32 s503-d32 544 40 s503-d40 544 50 s503-d50 600 63 s503-d63 646 ul 1077 csa c22.2 vde 0641 iec 947-1 d ul 1077 csa c22.2 vde 0641 iec-898 k rated catalog list delivery wgt. oz. current number price class (1 pc.) s501-d20 s502-d13 s503-k6 discount schedule cb10 0.1 0.15 s501-k0.15 $ 182 0.14 0.21 s501-k0.21 182 0.2 0.3 s501-k0.3 182 0.28 0.42 s501-k0.42 182 0.38 0.58 s501-k0.58 182 0.53 0.8 s501-k0.8 182 0.73 1.1 s501-k1.1 182 1 1.5 s501-k1.5 182 1.4 2.1 s501-k2.1 182 2 3 s501-k3 182 2.8 4.2 s501-k4.2 182 b8.90 3.8 5.8 s501-k5.8 182 5.3 8 s501-k8 182 7.3 11 s501-k11 182 10 15 s501-k15 182 14 20 s501-k20 182 18 26 s501-k26 182 23 32 s501-k32 202 29 37 s501-k37 202 34 41 s501-k41 226 38 45 s501-k45 226 0.1 0.15 s502-k0.15 356 0.14 0.21 s502-k0.21 356 0.2 0.3 s502-k0.3 356 0.28 0.42 s502-k0.42 356 0.38 0.58 s502-k0.58 356 0.53 0.8 s502-k0.8 356 0.73 1.1 s502-k1.1 356 1 1.5 s502-k1.5 356 1.4 2.1 s502-k2.1 356 2 3 s502-k3 356 b 17.85 2.8 4.2 s502-k4.2 356 3.8 5.8 s502-k5.8 356 5.3 8 s502-k8 356 7.3 11 s502-k11 356 10 15 s502-k15 356 14 20 s502-k20 356 18 26 s502-k26 356 23 32 s502-k32 392 29 37 s502-k37 392 34 41 s502-k41 442 38 45 s502-k45 442 0.1 0.15 s503-k0.15 518 0.14 0.21 s503-k0.21 518 0.2 0.3 s503-k0.3 518 0.28 0.42 s503-k0.42 518 0.38 0.58 s503-k0.58 518 0.53 0.8 s503-k0.8 518 0.73 1.1 s503-k1.1 518 1 1.5 s503-k1.5 518 1.4 2.1 s503-k2.1 518 2 3 s503-k3 518 b 25.36 2.8 4.2 s503-k4.2 518 3.8 5.8 s503-k5.8 518 5.3 8 s503-k8 518 7.3 11 s503-k11 518 10 15 s503-k15 518 14 20 s503-k20 518 18 26 s503-k26 518 23 32 s503-k32 574 29 37 s503-k37 574 34 41 s503-k41 644 s500 d & k 1 2 3 5 10 20 30 d 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc ac seconds multiple of rated current 1 2 3 5 10 20 30 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 ac dc k seconds multiple of rated current 12 8 delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
1 .34 abb control inc. ac 1600 3/00 pro m rated catalog list delivery weight current number price class (oz.) 1 pc s500uc 600 vac/vdc rated catalog list delivery weight current number price class (oz.) 1 pc 6 s501uc-b6 $ 226 10 s501uc-b10 226 13 s501uc-b13 226 16 s501uc-b16 226 20 s501uc-b20 226 c8.90 25 s501uc-b25 226 32 s501uc-b32 226 40 s501uc-b40 226 50 s501uc-b50 258 63 s501uc-b63 292 6 s502uc-b6 442 10 s502uc-b10 442 13 s502uc-b13 442 16 s502uc-b16 442 20 s502uc-b20 442 c 17.85 25 s502uc-b25 442 32 s502uc-b32 442 40 s502uc-b40 442 50 s502uc-b50 502 63 s502uc-b63 568 ul 1077 csa c22.2 vde 0660 b s502uc-b16 discount schedule cb10 s501uc-b40 s503uc-b50 s504uc-b25 6 s503uc-b6 $ 646 10 s503uc-b10 646 13 s503uc-b13 646 16 s503uc-b16 646 20 s503uc-b20 646 c 25.36 25 s503uc-b25 646 32 s503uc-b32 646 40 s503uc-b40 646 50 s503uc-b50 734 63 s503uc-b63 832 6 s504uc-b6 908 10 s504uc-b10 908 13 s504uc-b13 908 16 s504uc-b16 908 20 s504uc-b20 908 c 35.75 25 s504uc-b25 908 32 s504uc-b32 908 40 s504uc-b40 908 50 s504uc-b50 1030 63 s504uc-b63 1164 s500 (uc) b 0.01 0.1 10 100 1000 10,000 1 1 2 3 5 10 20 30 b 0.05 0.5 50 500 5000 5 dc ac 7 seconds multiple of rated current delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .35 ac 1600 3/00 pro m s500 uc 600 vac/vdc rated catalog list delivery weight current number price class (oz.) 1 pc 0.1 0.15 s503uc-k0.15 $ 712 0.14 0.21 s503uc-k0.21 712 0.2 0.3 s503uc-k0.3 712 0.28 0.42 s503uc-k0.42 712 0.38 0.58 s503uc-k0.58 712 0.53 0.8 s503uc-k0.8 712 0.73 1.1 s503uc-k1.1 712 1 1.5 s503uc-k1.5 712 1.4 2.1 s503uc-k2.1 712 2 3 s503uc-k3 712 2.8 4.2 s503uc-k4.2 712 c 25.36 3.8 5.8 s503uc-k5.8 712 5.3 8 s503uc-k8 712 7.3 11 s503uc-k11 712 10 15 s503uc-k15 712 14 20 s503uc-k20 712 18 26 s503uc-k26 712 23 32 s503uc-k32 814 29 37 s503uc-k37 814 34 41 s503uc-k41 910 38 45 s503uc-k45 910 0.1 0.15 s504uc-k0.15 996 0.14 0.21 s504uc-k0.21 996 0.2 0.3 s504uc-k0.3 996 0.28 0.42 s504uc-k0.42 996 0.38 0.58 s504uc-k0.58 996 0.53 0.8 s504uc-k0.8 996 0.73 1.1 s504uc-k1.1 996 1 1.5 s504uc-k1.5 996 1.4 2.1 s504uc-k2.1 996 2 3 s504uc-k3 996 c 35.75 2.8 4.2 s504uc-k4.2 996 3.8 5.8 s504uc-k5.8 996 5.3 8 s504uc-k8 996 7.3 11 s504uc-k11 996 10 15 s504uc-k15 996 14 20 s504uc-k20 996 18 26 s504uc-k26 996 23 32 s504uc-k32 1142 29 37 s504uc-k37 1142 34 41 s504uc-k41 1276 38 45 s504uc-k45 1276 s503uc-k8 s504uc-k20 discount schedule cb10 rated catalog list delivery weight current number price class (oz.) 1 pc ul 1077 csa c22.2 vde 0660 k 0.1 0.15 s501uc-k0.15 $ 250 0.14 0.21 s501uc-k0.21 250 0.2 0.3 s501uc-k0.3 250 0.28 0.42 s501uc-k0.42 250 0.38 0.58 s501uc-k0.58 250 0.53 0.8 s501uc-k0.8 250 0.73 1.1 s501uc-k1.1 250 1 1.5 s501uc-k1.5 250 1.4 2.1 s501uc-k2.1 250 2 3 s501uc-k3 250 2.8 4.2 s501uc-k4.2 250 c8.90 3.8 5.8 s501uc-k5.8 250 5.3 8 s501uc-k8 250 7.3 11 s501uc-k11 250 10 15 s501uc-k15 250 14 20 s501uc-k20 250 18 26 s501uc-k26 250 23 32 s501uc-k32 286 29 37 s501uc-k37 286 34 41 s501uc-k41 320 38 45 s501uc-k45 320 0.1 0.15 s502uc-k0.15 488 0.14 0.21 s502uc-k0.21 488 0.2 0.3 s502uc-k0.3 488 0.28 0.42 s502uc-k0.42 488 0.38 0.58 s502uc-k0.58 488 0.53 0.8 s502uc-k0.8 488 0.73 1.1 s502uc-k1.1 488 1 1.5 s502uc-k1.5 488 1.4 2.1 s502uc-k2.1 488 c 17.85 2 3 s502uc-k3 488 2.8 4.2 s502uc-k4.2 488 3.8 5.8 s502uc-k5.8 488 5.3 8 s502uc-k8 488 7.3 11 s502uc-k11 488 10 15 s502uc-k15 488 14 20 s502uc-k20 488 18 26 s502uc-k26 488 23 32 s502uc-k32 558 29 37 s502uc-k37 558 34 41 s502uc-k41 622 38 45 s502uc-k45 622 s500 (uc) k 1 2 3 5 10 20 30 uc-k 0.01 0.1 10 100 1000 10,000 1 0.05 0.5 50 500 5000 5 dc seconds multiple of rated current delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
1 .36 abb control inc. ac 1600 3/00 pro m accessories s500 electrical catalog list delivery wgt. oz. accessories number price class (1pc.) discount schedule cb8 s500-h11 auxiliary contacts auxiliary contacts 1 n.o./1 n.c. s500-h11 2 n.o. s500-h20 $ 84 b2.14 2 n.c. s500-h02 for field mounting left side bell alarm with auxiliary contacts 1 n.o./1 n.c. s500-s11 2 n.o. s500-s20 92 b2.14 2 n.c. s500-s02 for field mounting left side handle mechanism s500-rd3 100 b6.5 for use with 3 pole s500 mcbs and disconnect switch selector handles with 5mm shafts front mounting kit for 1 pole s500-me1 16 2.1 1 to 3 poles s500-me2 32 a2.9 1 to 7 poles s500-me3 64 3.6 electrical catalog list delivery wgt. oz. accessories number suffix price class (1pc.) undervoltage release 12 v -ua12 24 v -ua24 48 v -ua48 $ 266 b5.71 110 v -ua110 230 v -ua230 500 v -ua500 factory mount only. shunt trip 12 v -al12 24 v -al24 48 v -al48 224 b5.71 110 v -al110 230 v -al230 500 v -al500 factory mount only . acc. delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .37 ac 1600 3/00 pro m approvals: ul csa vde no. of poles: tripping characteristic: rated currents: rated voltage: ul single pole ul multi pole iec multi pole rated interrupting capacity: frequency: mounting position: standard mounting: terminals: service life at rated load: calibration temperature: technical data s500 approvals: ul 1077 1077 csa c22.2 - no.235 c22.2 - no. 235 vde 0641/6.78 0641/6.78 iec 947-2 no. of poles: 1,2,3, +n, +na 1,2,3, +n, +na tripping characteristic: b.c.d. k rated currents: 6 to 63a 0.1 to 45a rated voltage: ul/csa single pole 277vac 277vac ul/csa multi pole 600vac 600vac iec single pole 690vac 690vac rated interrupting capacity: single pole 6-25a 30ka/240vac 0.15-25a 30ka/240vac 14ka/277vac 14ka/277vac 32-63a 18ka/240vac 26-45a 18ka/240vac 14ka/277vac 14ka/277vac multi-pole 6-63a 14ka/480vac 6-63a 14ka/480vac 6ka/600vac 6ka/600vac frequency: 50/60 hz 50/60hz mounting position: optional optional standard mounting: 35 mm din rail 35 mm din rail terminals: conductors from 16-4awg conductors from 16-4awg (1-25sq mm ) (1-25sq mm ) service life at rated load: 20,000 operations 20,000 operations calibration temperature: 40 c40 c item s500-b, c, d s500-k item s500uc-b, k 1077 c22.2 0660 1,2,3, 4 b, k b: 6 to 63a k: 0.15 to 45a 277vac/250vdc 600vac/600vdc 690vac/750vdc b single pole: 6 25a 18ka/240vac 14ka/277vac 30ka/250vdc 32 63a 30ka/240vac 14ka/277vac 30ka/250vdc b two-pole: 6 63a 14ka/480vac 6ka/600vac 30ka/500vdc b three-pole: 6 63a 14ka/480vac 6ka/600vac 30ka/600vdc k single pole: 0.15 25a 30ka/240vac 14ka/277vac 30ka/250vdc 32 63a 18ka/240vac 14ka/277vac 30ka/250vdc k two-pole: 0.15 45a 14ka/480vac 6ka/600vac 30ka/500vdc k three-pole: 0.5 45a 14ka/480vac 6ka/600vac 30ka/600vdc 50/60hz optional 35 mm din-rail conductors from 16 to 4awg (1-25sq mm ) 20,000 operations 40 c tech data
1 .38 abb control inc. ac 1600 3/00 pro m approximate dimensions s500 accessories s500-rd3 handle mechanism s500 front mounting kit 0.24 6 1.14 29 3.62 92 2.22 56.5 3.15 80 1.73 44 3.64 92.5 2.95 75 1.97 50 0.98 25 c l 2.95 75 1.77 45 2.91 74 1.81 46 l l + 1.02 26 0.31 8 3.31 84 4.41 112 " l " 2.00 51 c l c l cut-out 0.24 d 6 d l + 0.51 13 3.15 80 1.60 40.7 s500 dims 00.00 00.00 inches millimeters
abb control inc. 1 .39 ac 1600 ?3/00 pro m residual current devices f360 series description rcds provide ground fault equipment protection by monitoring the leakage of current to ground. the f360 series will trip when ground faults are detected in excess of the gf trip rating of the rccb. these devices provide gf protection only and are used in series with standard mcbs which provide overload and short circuit protection. the f360 series can be used as a main device providing gf protection for several mcb branch devices. 2 pole 4 pole the f360 series are ul1053 recognized for use in 277/480vac applications. the f362 is for use in single phase/two wire or two wire systems. the f364 is for use in three phase/four wire systems.
1 .40 abb control inc. ac 1600 3/00 pro m selection guide residual current devices, f362, f364 above devices are ul 1053 recognized and iec 1008 approved. f362 two pole 10ma 16 f362-16/0.01 $ 590 480vac 30ma 25 f362-25/0.03 408 40 f362-40/0.03 464 63 f362-63/0.03 660 100ma 25 f362-25/0.1 408 40 f362-40/0.1 464 b113.8 63 f362-63/0.1 660 300ma 25 f362-25/0.3 288 40 f362-40/0.3 320 63 f362-63/0.3 474 f364 four pole 30ma 25 f364-25/0.03 426 480vac 40 f364-40/0.03 486 63 f364-63/0.03 726 100ma 25 f364-25/0.1 426 40 f364-40/0.1 486 63 f364-63/0.1 726 b119.0 300ma 25 f364-25/0.3 302 40 f364-40/0.3 342 63 f364-63/0.3 494 500ma 25 f364-25/0.5 302 40 f364-40/0.5 342 63 f364-63/0.5 494 breaker gf trip rated catalog list delivery suggested wgt. oz level current number price class order qty (1 pc.) residual current breakers approximate dimensions f262 f364 discount schedule cb14 3.54 90 2.76 70 2.76 70 1.77 45 1.98 50.2 2.91 74 wiring diagram 1 3 5 7n 2 4 6 8n trip unit test ct 1 f364 1 3 2 4 trip unit test ct f362  for use on 3p/3w systems, add jumper between 4 and 8n for operation of test button. f series delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery 00.00 00.00 inches millimeters
abb control inc. 1 .41 ac 1600 ?3/00 pro m modular installation equipment system pro m description safe connection by box terminals captive screws with pozidrive slotted head, pozidrive system, gr. 1 snap-on labels available quick mounting with snap-on clip, easily accessible and detachable at the bottom protection against unintentional direct touch system approach for control and circuit protection compact size that dimensionally matches the s2 mcb series control and pilot functions can be along side protective devices din rail mounted with 45 mm front opening for use in auxiliary and logic devices provide additional user functions for system control and operation include pushbuttons, indicating lights and selector switches abb system pro m compatibility most devices are both ul 508 recognized and are iec compliant labeled with the ce mark
1 .42 abb control inc. ac 1600 3/00 pro m modular installation equipment switches, 240vac 16 & 25a e221-10 discount schedule cb20 type rated catalog list delivery suggested weight (oz.) current number price schedule order qtys 1 piece switches note: above devices are ul 508 recognized and iec certified. a300 pilot duty 1 pole 16 e221-4 99 b10 2.12 2 pole 16 e221-4/2 147 2.47 1 pole 25 e222-4 150 b10 2.12 form ??switches (i-o-ii, hand-off-automatic) 1 change-over contact 16 e221-6 69 b10 2.12 2 change-over contacts 16 e221-6/2 125 2.47 1 change-over contact 25 e222-6 128 b10 2.12 form ??switches 1 n.o. + 1 n.c. 16 e221-11 $ 90 2 n.o. + 2 n.c. 16 e221-22 177 b10 2.46 3 n.o. + 1 n.c. 16 e221-31 177 1 n.o. 16 e221-10 59 1.94 2 n.o. 16 e221-20 110 b10 2.12 3 n.o. 16 e221-30 120 2.29 4 n.o. 16 e221-40 159 2.47 1 n.o. + 1 n.c. 25 e222-11 140 2.47 1 n.o. 25 e222-10 107 1.94 2 n.o. 25 e222-20 141 b10 2.12 3 n.o. 25 e222-30 159 2.29 4 n.o. 25 e222-40 239 2.47 pilot devices delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .43 ac 1600 3/00 pro m modular installation equipment disconnect switches 45, 63, 80 & 100a single pole, 240v 45 e241/45 $ 54 63 e271/63 60 b10 2.82 80 e271/80 72 100 e271/100 96 two pole, 415v 45 e242/45 114 63 e272/63 126 b 5 6.17 80 e272/80 150 100 e272/100 204 three pole, 415v 45 e243/45 174 63 e273/63 192 b 3 9.52 80 e273/80 228 100 e273/100 306 four pole, 415v 45 e244/45 234 63 e274/63 258 b 2 12.87 80 e274/80 306 100 e274/100 410 isolator switches the e240/270 series operate as disconnect switches and are typically used as a main disconnect for several branch mcb devices. the isolator switches offer no overcurrent protection. the e240/270 series is the same physical size and shape as the s260, s270 & s280 series. the switches include dual function terminals and can be connected via standard abb busbar through the upper or lower terminals. type rated catalog list delivery suggested weight (oz.) current number price schedule order qtys 1 piece single pole two pole three pole four pole discount schedule cb20 above devices are iec certified. disc. sws. delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
1 .44 abb control inc. ac 1600 3/00 pro m modular installation equipment pilot devices pushbutton, 1 n.o. + 1 n.c. contact e225-11f e227-10e type catalog list delivery pack weight (oz.) number price schedule units pcs. 1 piece discount schedule cb20 24 vac/dc e10/24 120 vac/dc e10/110 24 a 1 0.14 220 vac/dc e10/220 lamps clear e229-b/110 red e229-c/110 green e229-d/110 93 a10 1.59 yellow e229-e/110 blue e229-g/110 pilot light with lamp, 120 vac clear e227-10b/110 red e227-10c/110 green e227-10d/110 100 a10 1.94 yellow e227-10e/110 blue e227-10g/110 illuminated pushbutton, 1 n.o. contact with lamp, 120 vac grey e225-11b red e225-11c green e225-11d $ 75 a10 1.94 yellow e225-11e black e225-11f blue e225-11g pilot devices 24 vac, 60 hz e233-24/60 b 120 vac, 60 hz e233-120/60 $ 130 a 1 0.045 240 vac, 60 hz e233-240/60 b type catalog list delivery pack weight (kg) number price schedule units pcs. 1 piece elapsed time meter special features safe connection via box terminals captive screws with phillips/slotted head, posidriv sysem, gr. 1 snap-on labels available protection against unintentional touch acc. to din vde 0106 part 100 lenses and pushbuttons in six colors note: above devices are ul 508 recognized and iec certified. non-resettable 100,000 hours (99999.99) delivery class a - standard item, stock to 2 weeks lead time b - stock to 4 weeks lead time c - 6 to 8 week lead time d - 10 to 12 week lead time e - call for delivery
abb control inc. 1 .45 ac 1600 3/00 pro m components for quick mounting onto din rails (35 mm ) mounting depth: 68 mm mounting width: 1, 2, 3 and 4 pole switches = 17.5 mm (= 1 module) e220 switches, 16 & 25a switching capacity: 1.25 i n , 1.1u n , cos j = 0.6 short-circuit withstanding capacity: 3 ka, 380v, cos j = 0.9 toggle sealable: in on and off positions connection cross-sections: up to 1 x 6 mm 2 or 2 x 2.5 mm 2 rated ac voltage: 240 vac ul/csa (e171252) 250/440 vac iec e240/270 disconnect switches, 45, 63, 80, & 100a switching capacity: 1.25 i n , 1.1u n , cos j = 0.3 short-circuit withstanding capacity: e240 = 10ka, e270 = 25ka rms connection cross-sections: e240 up to 25 mm 2 e270 up to 50 mm 2 rated ac voltage: 240/400/415 vac e series components for quick mounting onto din rails (35 mm ) mounting depth 68 mm mounting width: 17.5 mm (=1 module) color: ral 7035, grey connection cross sections: up to 1 x 6 mm 2 or 2 x 2.5 mm 2 rated current: 16a rated voltage: 250 vac iec rated voltage: 240 vac ul/csa (e171252) modular installation equipment technical data terminal markings terminal assignments for pushbuttons and indicator lights illuminated pushbutton disconnect switches 1 no 1 2 2 no 1 2 3 4 3 no 1 2 3 4 5 6 1 2 3 4 5 6 7 8 4 no switches 2 no & 2 nc 3 no & 1 nc 1 2 3 4 5 6 7 8 2 no 1 2 3 4 1 2 3 4 5 6 7 8 3 no 7 8 1 2 3 5 6 2 no 1 2 3 7 8 1 no 1 2 3 form "c" switches (hand - off- auto) 2 pole 1 2 3 i ii 0 7 8 5 1 pole 1 2 3 i ii 0 form "c" switches 1 2 3 7 8 5 2 pole 1 pole 1 2 3 5 7 1 3 2 6 4 8 pilot light 1 no 1 2 max 2w pushbutton 1 no illuminated 5 6 1 2 max 2w 1 no & 1 nc 1 2 7 8 1 2 5 7 1 3 2 6 4 8 disc. sws.
1 .46 abb control inc. ac 1600 3/00 pro m modular installation equipment approximate dimensions e220, 16 & 25a 2.52 64.0 3.35 85.0 0.69 17.5 1.99 50.5 1.77 45.0 pilot light pushbutton 2.52 64.0 3.35 85.0 0.69 17.5 1.99 50.5 1.77 45.0 3.35 85.0 0.69 17.5 e220 e240/270 2.52 64.0 1.99 50.5 1.77 45.0 3.52 89.5 0.69 17.5 1.38 35.0 1.38 52.5 2.76 70.0 e233 1.77 45.0 2.52 64.0 1 2 3 4 5 9 9 3.35 85.0 0.69 17.5 1.97 50.0 dims 00.00 00.00 inches millimeters


▲Up To Search▲   

 
Price & Availability of S291-C125

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X